Viscoelastic Tape System

Viscoelastic Corrosion Protection Tape

A cold-applied, permanently non-curing viscoelastic wrap that cold-flows around imperfections and complex steel details.

Viscoelastic Corrosion Protection Tape product and application view

Overview

System role and composition

Primary self-sealing corrosion protection wrap

  • Viscoelastic corrosion protection compound
  • Matching outer wrap selected for mechanical and environmental protection

Key advantages

Approved product and system characteristics

Statements below apply only to this product or stated system and must be read with the listed conditions and qualifiers.

01

Cold-applied and permanently non-curing

02

Cold-flow with self-sealing / self-healing behavior around imperfections

03

Zero VOC, solvent-free and no odor

04

No hot work and no primer required when used as specified

05

Suitable for rehabilitation of damaged 3PE/FBE coatings

06

Suitable for flanges, valves, pumps and complex geometries

07

No cracking or embrittlement

08

Strong bonding over the stated service range

Typical applications

Where this solution is considered

  • Damaged 3PE/FBE coating rehabilitation
  • Flanges, valves and pumps
  • Pipeline fittings and irregular components

Typical Sizes and Packaging

  • Nominal thickness: 1.8 mm
  • Selected grades: 1.8–2.2 mm
  • Width: 50–300 mm
  • Length: 10 m/roll

Available grades

  • Selected grade application range: −45°C to +95°C

Product formats, packaging and available grades may vary by application and order requirements. Please confirm the current configuration with our team.

Documented performance

Selected values from the 2026 technical data sheet

These values apply to the stated viscoelastic tape configuration and test conditions. Confirm the selected grade and current TDS before specification.

PropertyDocumented valueMethod
Peel strength at 23°C≥5 N/cm on steel and PE; coverage ≥95%GB/T 2792
Peel strength at −45°C≥50 N/cm on steel; coverage ≥95%GB/T 2792
Impact resistance with outer wrap≥15 J at −45°C and 23°CSY/T 0315

Installation overview

Confirm the complete procedure before work begins

  1. Inspect the substrate, geometry, existing coating and service environment.
  2. Prepare the surface to the requirement stated for the selected system.
  3. Apply the compatible primer or profiling material where the system calls for it.
  4. Install the primary tape with the specified overlap, tension and termination treatment.
  5. Add compatible outer protection where required, then inspect continuity and terminations.

Matching components

This overview supports early evaluation. The current TDS and approved project procedure remain the controlling installation documents.

Gallery

Product and application views

Technical documents

Request the documents relevant to your evaluation

Product catalog, technical data, safety information and installation guidance are supplied according to the selected product and application.

Content source: Zhuohuang Technical Data Sheets UAE 2026 (primary); Zhuohuang Product Catalogue UAE 2026 (secondary).

Frequently asked questions

Is a primer required?

No primer is required when the tape is used as specified within its stated system.

Is hot work required?

No. The system is cold-applied and is described for use without hot work.

Technical inquiry

Confirm the right configuration for your asset

Share the asset type, geometry, existing coating, operating environment and documentation requirements.

Discuss This Product